Toll Free () International () Chat with Us. 5 (1 Reviews) | Catalog: G1 | Model: Inficon D-TEK Stratus. Compare. D-TEK Stratus Refrigerant Leak Detector and Portable Monitor Includes next generation infrared sensor, lithium ion rechargeable battery, AC wall charger, DC car charger, extra-long probe, earbuds. Toll Free () International () Chat with Us. 0 reviews | Catalog: G1 | Model: Inficon D-TEK STRATUS CO2. Compare. Includes CO2 sensor only. Innovative cloud hunter mode with ppm readout helps locate leaks faster than ever. Cloud hunter and pinpoint modes is like having two leak detectors in one. apagar el detector D-TEK Stratus. NOTA: Si la pantalla no se enciende,significa que el nivel de la batería es muy bajo y debe cargarse. El D-TEK Stratus se puede utilizar mientras se carga. b. El D-TEK Stratus iniciará una fase de calentamiento de entre 45 y 90 segundos. c. Para cambiar de modo, pulse el botón MODE. Se alternará entre.
Toll Free () International () Chat with Us. 0 reviews | Catalog: G1 | Model: Inficon D-TEK STRATUS CO2. Compare. Includes CO2 sensor only. Innovative cloud hunter mode with ppm readout helps locate leaks faster than ever. Cloud hunter and pinpoint modes is like having two leak detectors in one. D-TEK Select is a reliable handheld refrigerant leak detector that utilizes infrared absorption technology. It is highly sensitive to all CFC, HCFC and HFC r. refrigerant leak detector, the original D-TEK revolutionized the field. Now we have built on that technology leadership to create D-TEK Select. This next-generation refrigerant leak detector uses an innovative infrared absorption sensing cell that is extremely sensitive to all refrigerants—and only refrigerants.
Using Your INFICON D-TEK CO2 WARNING DO NOT OPERATE THIS INSTRUMENT IN THE PRESENCE OF GASOLINE, NATURAL GAS, PROPANE, OR IN OTHER COMBUSTIVE ATMOSPHERES. Using the D-TEK CO2 is simple. Press the power switch once to turn the detector ON. The green ON indicator lamp will illuminate, and the yellow indicator lamps. to continue using the D-TEK Select. Using the Manual Zero Mode The D-TEK Select's automatic suppression of background contamination can be disabled, allowing for a continuous display of a leak without "zeroing it out". When the D-TEK Select is set in the manual zero mode, the technician may manually reset or zero the detector. a. Place the tip of D-TEK Stratus as close as possible to the suspected leak. Do not block the air flow. b. Slowly ( to 5 cm [1 to 2 in.] per second) move the probe past each possible leak point. If a leak is detected, D-TEK Stratus will alarm and the on-screen indicators will illuminate. NOTE: In Pinpoint mode, D-TEK Stratus will automatically.
0コメント